Services Offered

Quality Assurance, Customer Satisfaction

Its key professionals brought the company many years of varied experience in the technical and management field. Its experience and expertise is supplemented by an extensive utilization of computer for power system analysis, calculation and computer-aided design, and drafting (CADD) technology using AutoCAD and Intergraph System. NAR’s genuine concern for its clients, dedication to hard work, distinguished technical credentials, and impressive track record have earned the respect and confidence of its client.
Check out our clients
Predictive and preventive maintenance testing of substation equipment
Main Substation Switch Yard
  • High and Medium Voltage Circuit Breakers
  • Air Switches
  • Outdoor Bus Structure
  • Porcelain Insulators
  • Lightning Arresters
  • Power Transformers
  • Protective Relays
  • Power Cable
  • Associated Groundings

Low Voltage System
  • Switchgear (General)
  • Circuit Breakers
  • Bus Duct
  • Protective Relays
  • Instruments Transformers
  • Metering Instruments and Controls
  • Motor Control Center
  • Automatic Transfer Switch
  • Battery System
  • Associated Groundings
thermographic scanning operation
Thermal imaging is also an ideal inspection method for predictive maintenance of electrical systems, including motors, drives, electrical boxes, and distribution system junctions. This method can identify whether the problem is a loose connection, corroded element, or a short or overloaded circuit. 
Ultrasonic Detection Testing and Machinery Health Monitoring
​Ultrasonic Testing involves the use of an ultrasonic acoustical emissions detector that can capture sound waves above the range of human hearing. It can identify leaks in compressed gas systems, and internal problems in steam traps, valves and pumps.

Ultrasonic Testing – Application Summary
  • Leak detection
    • Compressed air/gas leak detection
    • Vacuum leak detection
    • Bearing and mechanical system analysis
  • Electrical/Corona discharge detection
​
Ultrasonic Testing – Benefits Summary
  • Discovery of equipment malfunctions prior to failure
  • Quantifiable savings estimates
  • Prevention of “flashover” due to tracking and arcing in high-voltage environments
Fault investigation and trouble shooting
power quality audit
​Power Quality Audits identifies power quality issues. This will further help you to address reliability and stability concerns before they actually impact on your facilities performance and more important on bottom line of organization. 

Analyzing power quality is an effective way to identify electrical disturbances without having to shut down the system. It can analyze the power quality of your electrical installation by performing measurements during operation to identify disturbances. These disturbances can take many forms ranging from: harmonics, voltage sags/swells/ unbalances, flicker, and transients etc. Our specialized measurement equipment enables us to accurately monitor and record voltage, current, power, harmonics and many other relevant parameters. Short term testing can be used to record the behavior of specific equipment. Long term testing can be used to record ongoing power quality parameters and detect intermittent electrical supply issues.
power system analysis 
1. Network Analysis
  • Short-Circuit ANSI
  • Short-Circuit IEC
  • Arc Flash
  • Load Flow
  • Motor Acceleration
2. Power Quality
  • Harmonic Load Flow
  • Frequency Scan
  • Harmonic Filters
3. Protective Devices
  • Coordination & Selectivity
  • Sequence-of-operation
  • Relay Test Set Interface
4. Relay Testing
  • Relay Test Set Equipment
  • Relay Test Set Software
5. Ground Grid System
  • Finite Element Method
  • IEEE 80 & 655 Methods
6. Dynamics and Transients 
  • Transient Stability
  • Generator Start-up​
  • Wind Turbine Generator
  • ​​User-Defined Dynamic Model
  • Parameter Estimation
7. Cable Systems
  • Underground Thermal Analysis
  • Cable Pulling
  • Cable Ampacity
  • Cable Sizing
8. Distribution Systems
  • Unbalanced Load Flow
  • Optimal Power Flow
  • Optimal Capacitor Placement
  • Reliability Assessment
9. Transmission Line
  • Line Constant
  • Line Ampacity
  • Sag & Tension
  • HV DC Transmission Link
10. Real-Time Monitoring and Simulation
  • Monitoring & Control
  • Energy Cost Analysis
  • State Estimation
  • Real-Time Simulation
  • Playback / Trending
Contact Us
​EMERGENCY RESPONSE AND SERVICES 24 HOUR ON CALL  |  +63 917 587 7733

ADdress

Main Office: 
​
811 Aurelio Hall, Stall A, Rizal Street, Brgy Zone
Luisiana, Laguna

Field Office:
Unit 19 Ciannat Complex Bldg. Marcos Highway, Brgy. Mayamot
Antipolo City


Telephone

(02) 853 155 94
(02) 840 141 71

Email

narpowersystem@pldtdsl.net